{"id":"3564a496-65a5-4e8f-9ae0-a65a5d8541f6","name":"Ecogate, Inc.","entity_type":"company","domain":"ecogate.com","url":"https://optimly.ai/brand/ecogate-inc","is_claimed":false,"categories":["manufacturing-industrial"],"headers":[{"header":"Overview","sections":[{"key":"short_description","label":"Tagline","shape":"text","content":"Ecogate provides demand-based industrial ventilation control for dust, fume, and mist collection systems.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"description","label":"Description","shape":"text","content":"Ecogate makes industrial ventilation respond to production by directing airflow to active workstations and adjusting fan speed in real time. Its systems are designed to reduce energy use, maintain minimum transport velocities, and improve visibility into ventilation performance.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"}]},{"header":"Identity","sections":[{"key":"mission","label":"Mission","shape":"text","content":"Make industrial ventilation respond to production by matching airflow to real-time demand.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"website","label":"Website","shape":"text","content":"https://ecogate.com","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"voice_tone","label":"Voice & tone","shape":"text","content":"Technical, engineering-focused, practical, and efficiency-oriented, with emphasis on safety, measurable savings, and system performance.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"}]},{"header":"Offerings","sections":[{"key":"problem_solved","label":"Problem solved","shape":"text","content":"Conventional industrial ventilation systems often run full airflow even when only some workstations are active, wasting fan electricity, increasing make-up-air and HVAC costs, creating excess noise, and potentially compromising minimum duct transport velocities.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"core_capabilities","label":"Core capabilities","shape":"text","content":"Demand-based control of dust, fume, and mist collection\nReal-time airflow and duct-velocity measurement\nAutomatic Smart Gate operation for active workstations\nFan-speed regulation using variable frequency drives\nMaintenance of minimum conveying and transport velocities\nIntegration with workstation sensors, machine signals, and process controls\nVentilation system evaluation, engineering, design, installation, commissioning, and training\nBrowser-based monitoring and historical analytics for power, savings, airflow, pressure, utilization, and workstation activity","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"products","label":"Products / SKUs","shape":"text","content":"greenBOX controllers, including greenBOX Nxt\nSmart Gates and rotating blade gates\nPower Master and ABB ACS880 variable frequency drives\nAC/DC Volt Sensors\nAuto Shut-Off Timers\nAveraging Air Velocity Sensor (AAVS)\nEcogate Analytics\nDust Collector Interfaces","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"pricing","label":"Pricing","shape":"text","content":"Public product listings include a 4-inch Gate Body at $436, AC/DC Volt Sensor at $100, Auto Shut-Off Timer at $100, Averaging Air Velocity Sensor at $1,254, and ABB ACS880 VFDs from $2,142. System projects are evaluated through savings and system reviews or engineering analysis; project pricing is not stated.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"}]},{"header":"Audience","sections":[{"key":"target_industry","label":"Target industry","shape":"text","content":"Industrial dust, fume, and mist collection across woodworking, pharmaceuticals and laboratories, metalworking and welding, aerospace and automotive, food processing, education and makerspaces, small shops, large factories, and enterprise facilities.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"customer_base","label":"Customer base","shape":"text","content":"Industrial manufacturers, laboratories, pharmaceutical production facilities, research and development facilities, educational makerspaces, and other organizations operating variable-load collection systems. The site references GlaxoSmithKline, the United States Navy, Tesla, Unilever, Andersen Windows, Sauder Woodworking, Metrie, Svante, Upsher-Smith, and Fortune Pharmacal.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"icp","label":"Ideal customer profile","shape":"text","content":"Facilities with dust, fume, or mist collection systems serving multiple workstations with variable production demand, especially organizations seeking to reduce fan electricity, make-up-air and HVAC costs, noise, or the need for immediate collection-system expansion.","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"use_cases","label":"Use cases","shape":"text","content":"Demand-based dust collection in woodworking facilities\nFume extraction for metalworking and welding\nDust collection in pharmaceutical production and laboratories\nVentilation control for aerospace and automotive manufacturing\nFood-processing collection systems\nCollection systems in schools, universities, and makerspaces\nRetrofitting existing fans, collectors, ductwork, and controls\nMaintaining minimum duct transport velocity while reducing excess airflow","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"},{"key":"customer_outcomes","label":"Customer outcomes","shape":"text","content":"About 66% average reduction in dust-collection fan electricity, according to the site\nTypical stated return on investment of 1–3 years, often under two years\nReduced make-up-air volume and HVAC energy use\nLower operating noise by keeping inactive collection drops closed\nMaintained minimum transport velocities to reduce dust settling and related safety risks\nImproved visibility into fan power, savings, airflow, pressure, utilization, and workstation activity\nPotential avoidance of capital costs by identifying available capacity for additional workstations\nReduced contamination risk in laboratory and pharmaceutical environments","source_type":"1p_website","source_label":"Brand's website","source_url":"https://ecogate.com","updated_at":"2026-11-07T05:40:12.718098+00:00"}]}],"last_refreshed_at":"2026-11-07T05:40:12.730864+00:00","last_changed_at":"2026-11-07T05:40:12.741009+00:00","claim_url":"https://app.optimly.ai/sign-up?claim=3564a496-65a5-4e8f-9ae0-a65a5d8541f6"}